Product Selection Tool

This easy-to-use product selection tool is organized by amperage

STEP ONE:  Select the tab your amperage requirement falls into.

STEP TWO:  Review the features for each of the products.

STEP THREE:  Click the link to the product that matches your requirements.

 

Prior to selecting an interconnect solution from Anderson Power Products ®, we recommend gathering all of your information on the product selection worksheet. This, along with the tool below will aid you in quickly identifying the best product for your particular needs.

Product Selection Worksheet

Up to 55 Amps


 

Up to 55 Amps Primary Positions Signal
Positions
Connector Attributes
Amps (UL) (up to) Amps (CSA) (up to) Wire Sizes
AWG
 Wire Sizes
mm²
Quantity of Positions
(up to)
First Mate Ground Wire PCB Bus Bar Quantity of Positions
(up to)
Touch Safe Sealed Blind Mate
4 Position Solar SPEC Pak®  20 26 24 to 10 0.25 to 4.0 4     16  
3 Pole Mini PL SPEC Pak®  22 16 24 to 12 0.25 to 2.5 3     *  
5 Pole Mini PL SPEC Pak®  23 16 24 to 12 0.25 to 2.5 3     *  
MARC Connector 29 29 20 to 10 0.25 to 6.0 8          
PowerMod®  30 30 24 to 12 0.25 to 2.5 3 to 30   *    
SAF-D-GRID, AC 300 Volt 30 30 18 to 10 0.75 to 4.0 3          
SAF-D-GRID, DC 400 Volt  30  30  18 to 10  0.75 to 4.0   ●  ●  ●     ●     
PP10 & PP30, Pin & Socket  30 30 16 to 10 1.3 to 5.3 1+          
Power Drawer® 35 Amp  35 35 16, 12 8.4, 2.5 8   21    
4 Position SPEC Pak®  40 26 24 to 10 0.25 to 4.0 4     16  
6 Position SPEC Pak®  45 29 24 to 10 0.25 to 4.0 6        
Powerpole® Blindmate 45 40 20 to 10 0.25 to 4.0 2 to 8      
Powerpole® Pak 45 40 20 to 10 0.25 to 4.0 2 to 10        
SBS® Mini 52  35  20 to 10  0.25 to 4.0    ●        ●     
Powerpole® PP15 to 45  55 40 20 to 10 .25 to 6.0 1+        
SBE® 80 / SBO® 60  80 80 4 to 6 16 to 25 2       8    
Mid Power SPEC Pak®  80 50 12 to 6 2.5 to 13.3 4, 5     8    
SBS®50  110 75 16 to 6 1.3 to 13.3 2            
SBS®75G  110 75 16 to 6 1.3 to 13.3 3        
SBS®75X  110 75 16 to 6 1.3 to 13.3 2     4    
Powerpole® PP75  120 70 16 to 6 1.3 to 13.3 1+        
SB®50  120 50 16 to 6 1.3 to 13.3 2        


Note:  
• Amp ratings are stated per position and based on all positions being fully loaded.
• Evaluate and test all connectors thoroughly to ensure they are appropriate for the specific applications.
• UL amp rating:  Consult temperature rise charts for details.
• CSA  amp rating is based on a 30C rise.
• Quantity of Position equal to "1+" signify that the parts are stackable.
• Many of the mm² wire sizes are based on calculations. See the catalog for specific mm² wire sizes.
* Indicated primary positions may be used for signal.

55 to 150 Amps


 

55 Amps Up to 150 Amps Primary Positions Signal
Positions
Connector Attributes
Amps (UL) (up to) Amps (CSA) (up to) Wire Sizes
AWG
 Wire Sizes
mm²
Quantity of Positions
(up to)
First Mate Ground Wire PCB Bus Bar Quantity of Positions
(up to)
Touch Safe Sealed Blind Mate
High Power SPEC Pak® (H06)  75 40 12 to 6 2.5 to 13.3 6     8    
Power Drawer® 75 Amp  75 75 12, 8 2.5, 8.4 13   24    
SBE® 80 / SBO® 60  80 80 4 to 6 16 to 25 2       8    
Mid Power SPEC Pak®  80 50 12 to 6 2.5 to 13.3 4, 5     8    
SBS®50  110 75 16 to 6 1.3 to 13.3 2            
SBS®75G  110 75 16 to 6 1.3 to 13.3 3        
SBS®75X  110 75 16 to 6 1.3 to 13.3 2     4    
Powerpole® PP75  120 70 16 to 6 1.3 to 13.3 1+        
SB®50  120 50 16 to 6 1.3 to 13.3 2        
DIN, E Series (E80)  160 120 8 to 2 10 to 35 2       4    
SBE®160 & SBX®175  175 160 10 to 1/0 5.3 to 53.5 2       8    
High Power SPEC Pak® (H03)  190 100 6 to 1/0 13.3 to 42.2 3       8    
DIN, E Series (E160)  200 160 6 to 1/0 16 to 50 2       4    
PowerMod® HP, Series A  220 130 6 to 2 13.3 to 35 1 to 2        
Powerpole® PP120  240 110 10 to 1/0 5.3 to 53.5 1+              
SB®120  240 130 10 to 1 5.3 to 42.4 2          
High Power SPEC Pak® (H02)  240 140 6 to 3/0 13.3 to 85 2       8    
SB®175  280 175 10 to 1/0 5.3 to 53.3 2, 3          


Note: 
• Amp ratings are stated per position and based on all positions being fully loaded.
• Evaluate and test all connectors thoroughly to ensure they are appropriate for the specific applications.
• UL amp rating:  Consult temperature rise charts for details.
• CSA amp rating is based on a 30C rise.
• Quantity of Position equal to "1+" signify that the parts are stackable.
• Many of the mm² wire sizes are based on calculations. See the catalog for specific mm² wire sizes.

150 to 250 Amps


 

150 Amps up to 250 Amps Primary Positions Signal
Positions
Connector Attributes
Amps (UL) (up to) Amps (CSA) (up to) Wire Sizes
AWG
 Wire Sizes
mm²
Quantity of Positions
(up to)
First Mate Ground Wire PCB Bus Bar Quantity of Positions
(up to)
Touch Safe Sealed Blind Mate
High Power SPEC Pak® (H06)  75   12 to 6 2.5 to 13.3 6     8    
DIN, E Series (E80)  160   8 to 2 10 to 35 2       4    
SBE®160 & SBX®175  175 160 10 to 1/0 5.3 to 53.5 2       8    
High Power SPEC Pak® (H03)  190 100 6 to 1/0 13.3 to 42.2 3       8    
DIN, E Series (E160)  200 160 6 to 1/0 16 to 50 2       4    
PowerMod® HP, Series A  220 130 6 to 2 13.3 to 35 1 to 2        
SB® Smart Connector 230 - 10 to 1/0 5.3 to 53.5 2     16      
Powerpole® PP120  240 110 10 to 1/0 5.3 to 53.5 1+              
SB®120  240 130 10 to 1 5.3 to 42.4 2          
High Power SPEC Pak® (H02)  240 140 6 to 3/0 13.3 to 85 2       8    
SB®175  280 175 10 to 1/0 5.3 to 53.3 2, 3          
Power Clip®, Dual Pole (PCL03) 300 200 n/a n/a 2            
Power Clip®, Single Pole (PCL01) 300 200 n/a n/a 1            
SB® 2/0 340 200 2/0 70 2              
Powerpole® PP180  350 230 10 to 3/0 5.3 to 85 1+            
DIN, A Series (A320)  350 270 1/0 to 4/0 50 to 95 2       4    
DIN, E Series (E320)  350 260 1/0 to 4/0 50 to 95 2       4    
SBE® 320 / SBX® 350  350 320 1/0 to 300 mcm 53.5 to 152 2       8    
PowerMod® HP, Series B  450 250 1/0 to 4/0 53.5 to 95 1 to 2        


Note:  
Amp ratings are stated per position and based on all positions being fully loaded.
• Evaluate and test all connectors thoroughly to ensure they are appropriate for the specific applications.
• UL amp rating:  Consult temperature rise charts for details.
• CSA amp rating is based on a 30C rise.
• Quantity of Position equal to "1+" signify that the parts are stackable.
• Many of the mm² wire sizes are based on calculations. See the catalog for specific mm² wire sizes.

250 Amps & Up


 

250 Amps and Up Primary Positions Signal
Positions
Connector Attributes
Amps (UL) (up to) Amps (CSA) (up to) Wire Sizes
AWG
 Wire Sizes
mm²
Quantity of Positions
(up to)
First Mate Ground Wire PCB Bus Bar Quantity of Positions
(up to)
Touch Safe Sealed Blind Mate
SB®175  280 175 10 to 1/0 5.3 to 53.3 2, 3          
Power Clip®, Dual Pole (PCL03) 300 200 n/a n/a 2            
Power Clip®, Single Pole (PCL01) 300 200 n/a n/a 1            
SB® 2/0 340 200 2/0 70 2              
Powerpole® PP180  350 230 10 to 3/0 5.3 to 85 1+            
DIN, A Series (A320)  350 270 1/0 to 4/0 50 to 95 2       4    
DIN, E Series (E320)  350 260 1/0 to 4/0 50 to 95 2       4    
SBE® 320 / SBX® 350  350 320 1/0 to 300 mcm 53.5 to 152 2       8    
PowerMod® HP, Series B  450 250 1/0 to 4/0 53.5 to 95 1 to 2        
SB®350  450 350 1/0 to 300 mcm 53.5 to 152 2            


 
Note:  
Amp ratings are stated per position and based on all positions being fully loaded.
• Evaluate and test all connectors thoroughly to ensure they are appropriate for the specific applications.
• UL amp rating:  Consult temperature rise charts for details.
• CSA amp rating is based on a 30C rise.
• Quantity of Position equal to "1+" signify that the parts are stackable.
• Many of the mm² wire sizes are based on calculations. See the catalog for specific mm² wire sizes.