{"id":1829,"date":"2025-09-14T19:47:14","date_gmt":"2025-09-14T23:47:14","guid":{"rendered":"https:\/\/www.andersonpower.com\/saf-d-grid-best-practices-2\/"},"modified":"2026-05-22T14:20:02","modified_gmt":"2026-05-22T18:20:02","slug":"saf-d-grid-best-practices","status":"publish","type":"post","link":"https:\/\/www.andersonpower.com\/en-in\/saf-d-grid-best-practices\/","title":{"rendered":"Saf-D-Grid<sup>\u00ae<\/sup>: Best Practices for Adding Protection"},"content":{"rendered":"\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">Direct Connection for AC and DC Applications<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">APP\u00ae Saf-D-Grid\u00ae plugs and receptacles provide for the direct connection of AC and DC electronic devices to a grid powered by mains power, high efficiency DC sources or by renewable energy. The connector meets international safety requirements for hazardous, low voltage applications including IEC 950 and IEC60950.<\/p>\n<\/div>\n\n\n<div style=\"padding-top:var(--wp--preset--spacing--040-080);padding-bottom:var(--wp--preset--spacing--040-080);\" class=\"ideal-layout is-style-surface-dark ideal-content-with-background alignfull is-style-surface-dark ideal-content-with-background wp-block-ideal-layout\">\n\t<div class=\"ideal-layout__inner alignfull\">\n\t\t<div class=\"ideal-layout__section ideal-layout__section--1 wp-block-ideal-layout-section\">\n\t<div class=\"ideal-layout__section-inner content-flow\">\n\t\t\n\n<h2 class=\"wp-block-heading is-style-h3\">Maximizing Rack Space Without Sacrificing Power<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">One challenge facing the data center architect is to maximize usage of rack space. The Saf-D-Grid is size compatible with the IEC 60320 C13 and C14 connection system that is typically limited to 10A and 250 VAC. However, Saf-D-Grid enables greater power density by allowing up to 30A and 600V DC or AC within the same space. Saf-D-Grid facilitates increased wattage in AC systems that require more power within a standard footprint.<\/p>\n\n\t<\/div>\n<\/div>\n\t<\/div>\n<\/div>\n\n\n<div style=\"padding-top:var(--wp--preset--spacing--040-080);padding-bottom:var(--wp--preset--spacing--040-080);\" class=\"ideal-layout is-style-default alignfull is-style-default wp-block-ideal-layout\">\n\t<div class=\"ideal-layout__inner alignfull\">\n\t\t<div class=\"ideal-layout__section ideal-layout__section--1 wp-block-ideal-layout-section\">\n\t<div class=\"ideal-layout__section-inner content-flow\">\n\t\t\n<div\n\tclass=\"ideal-media-text alignwide wp-block-ideal-media-text\">\n\n\t\t\t<div class=\"ideal-media-text__media\">\n\t\t\t<img decoding=\"async\" width=\"1200\" height=\"400\" src=\"https:\/\/p1.aprimocdn.net\/idealindustries\/324a7736-c1a4-46eb-89b4-b3f000736c33\/ap-web_landing-pages_datacom-landing-page_Saf-D-Grid_Original%20file.png?fit=bounds&amp;width=1200&amp;height=400\" class=\"attachment-1280 size-1280\" alt=\"Promotional graphic for Saf-D-Grid connectors with features: Touch Safe, Power Density, Integral Latch, against a background of server racks.\" loading=\"lazy\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" srcset=\"https:\/\/p1.aprimocdn.net\/idealindustries\/324a7736-c1a4-46eb-89b4-b3f000736c33\/ap-web_landing-pages_datacom-landing-page_Saf-D-Grid_Original%20file.png?width=300&amp;height=100&amp;fit=bounds 300w, https:\/\/p1.aprimocdn.net\/idealindustries\/324a7736-c1a4-46eb-89b4-b3f000736c33\/ap-web_landing-pages_datacom-landing-page_Saf-D-Grid_Original%20file.png?width=600&amp;height=200&amp;fit=bounds 600w, https:\/\/p1.aprimocdn.net\/idealindustries\/324a7736-c1a4-46eb-89b4-b3f000736c33\/ap-web_landing-pages_datacom-landing-page_Saf-D-Grid_Original%20file.png?width=768&amp;height=256&amp;fit=bounds 768w, https:\/\/p1.aprimocdn.net\/idealindustries\/324a7736-c1a4-46eb-89b4-b3f000736c33\/ap-web_landing-pages_datacom-landing-page_Saf-D-Grid_Original%20file.png?width=1024&amp;height=341&amp;fit=bounds 1024w, https:\/\/p1.aprimocdn.net\/idealindustries\/324a7736-c1a4-46eb-89b4-b3f000736c33\/ap-web_landing-pages_datacom-landing-page_Saf-D-Grid_Original%20file.png?width=1200&amp;height=400&amp;fit=bounds 1200w, https:\/\/p1.aprimocdn.net\/idealindustries\/324a7736-c1a4-46eb-89b4-b3f000736c33\/ap-web_landing-pages_datacom-landing-page_Saf-D-Grid_Original%20file.png?width=1536&amp;height=512&amp;fit=bounds 1536w, https:\/\/p1.aprimocdn.net\/idealindustries\/324a7736-c1a4-46eb-89b4-b3f000736c33\/ap-web_landing-pages_datacom-landing-page_Saf-D-Grid_Original%20file.png?width=2048&amp;height=683&amp;fit=bounds 2048w, https:\/\/p1.aprimocdn.net\/idealindustries\/324a7736-c1a4-46eb-89b4-b3f000736c33\/ap-web_landing-pages_datacom-landing-page_Saf-D-Grid_Original%20file.png?width=2400&amp;height=800&amp;fit=bounds 2400w\" \/>\t\t<\/div>\n\t\n\t<div class=\"ideal-media-text__content content-flow\">\n\t\t\n\n<h2 class=\"wp-block-heading\">Touch Safe<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">To minimize the risk of personal contact with a hazardous voltage, safety standards require protection against finger access to live parts 50V and above. Unlike IEC 60320 connectors, Saf-D-Grid plug &amp; receptacle connectors both feature a Touch Safe shell with shock protection and both pass UL &amp; IEC finger probe (plug &amp; receptacle) and 3mm probe tests (receptacle). Further, with regard to power density Saf-D-Grid connectors are rated to carry up to 2x more current and 1.6x more voltage than the standard IEC 60320 C20.<\/p>\n\n\t<\/div>\n<\/div>\n\n\t<\/div>\n<\/div>\n\t<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">EMerge Alliance\u00ae Registered<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The APP Saf-D-Grid has a \u201cRegistered Product\u201d status with the EMerge Alliance\u00ae for 380 volt DC power distribution systems for use in data centers and telecom central offices. The EMerge Alliance Data\/Telecom Center Standard creates an integrated, open platform for power, infrastructure, peripheral device and control applications to facilitate the hybrid use of AC and DC power within data centers and telecom central offices. EMerge is leading the adoption of safe, resilient, economical and sustainable DC and hybrid AC\/DC. 380V is the global sweet spot for standardized components with the best balance of economics and safety. These standardized components are commonly used in power supply systems for today\u2019s computers, electric vehicles, solar power, etc.<\/p>\n<\/div>\n\n\n<div style=\"padding-top:var(--wp--preset--spacing--040-080);padding-bottom:var(--wp--preset--spacing--040-080);\" class=\"ideal-layout is-style-surface-dark ideal-content-with-background alignfull is-style-surface-dark ideal-content-with-background wp-block-ideal-layout\">\n\t<div class=\"ideal-layout__inner alignfull\">\n\t\t<div class=\"ideal-layout__section ideal-layout__section--1 wp-block-ideal-layout-section\">\n\t<div class=\"ideal-layout__section-inner content-flow\">\n\t\t\n\n<h2 class=\"wp-block-heading is-style-h3\">Built for 380V DC Distribution<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Power distribution at 380VDC has inherent advantages over lower voltages. This connector system provides a critical link in the broad scale adoption of 380VDC power distribution systems by providing a safe power interconnect for power supplies, power distribution units, and peripheral devices.<\/p>\n\n\t<\/div>\n<\/div>\n\t<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Safety Features<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Designed to Minimize Arcing<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Arcing Protection Housings contain the arc if connectors are mated or unmated while under load, minimizing risk to personnel. For its DC Arcing Tests, APP\u00ae created a DC Electronic Circuit to evaluate connector damage. Tests of existing IEC320 connectors on a 400V DC circuit demonstrated that the products did not survive 400VDC Arcing Damage. Testing resulted in a hole burnt through the primary conductive path of contacts.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To mitigate arcing, APP considered many solutions. Most were impractical or not cost effective. Ultimately, Saf-D-Grid\u00ae utilized contacts that are designed to minimize arcing along with housing geometries that contain the arc if connectors are mated or unmated while under load. The contacts have twice the spacing needed to extinguish the 400V DC Arc before the housings separate. The rugged polycarbonate housings are UL94 V-0 rated and over-molded to provide both strain relief during mating and un-mating.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Additional Safety Features<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Additional safety features include a first mate, last break contact to provide the safety of an earthing path before engagement of the power contacts. The connectors contain an integral latch to prevent accidental de-mating, preventing accidental power loss to critical equipment and revenue-consuming downtime. The connectors also offer tactile &amp; audible confirmation of a connection.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">A Note on Amperage Ratings<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The maximum amperage ratings provided in the specifications are based on use of APP\u2019s recommended assembly tooling and the maximum wire size for the connector being used. Amperage ratings are based on not exceeding the maximum operating temperature of the connector housing, factoring in an ambient temperature of 25\u00b0C or 77\u00b0F<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Saf-D-Grid builds on the proven contact technology used in SB and Powerpole<sup><sup>\u00ae<\/sup><\/sup> connectors by offering features required in 380-400VDC power distribution systems. <\/p>\n","protected":false},"author":13,"featured_media":"aprimo:d582d20cbf8346cf9a37b3f00073f5d8","comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"ideal_industries_subtitle":"","ideal_industries_page_buttons":[],"ideal_industries_color_scheme":"surface-dark","featured_image_focal_point_x":0.5,"featured_image_focal_point_y":0.5,"ideal_hide_featured_image_in_document":false,"footnotes":""},"categories":[511],"tags":[],"product_cat":[130],"industry":[500],"product-series":[],"product-application":[],"class_list":["post-1829","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-thought-leadership","product_cat-saf-d-grid","industry-data-centre"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Saf-D-Grid\u00ae: Best Practices for Adding Protection<\/title>\n<meta name=\"description\" content=\"Saf-D-Grid builds on the proven contact technology used in SB and Powerpole\u00ae connectors by offering features required in 380-400VDC power distribution systems.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.andersonpower.com\/en-in\/saf-d-grid-best-practices\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Saf-D-Grid\u00ae: Best Practices for Adding Protection\" \/>\n<meta property=\"og:description\" content=\"Saf-D-Grid builds on the proven contact technology used in SB and Powerpole\u00ae connectors by offering features required in 380-400VDC power distribution systems.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.andersonpower.com\/en-in\/saf-d-grid-best-practices\/\" \/>\n<meta property=\"og:site_name\" content=\"Anderson Power\" \/>\n<meta property=\"article:published_time\" content=\"2025-09-14T23:47:14+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-22T18:20:02+00:00\" \/>\n<meta name=\"author\" content=\"amanda\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"amanda\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/saf-d-grid-best-practices\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/saf-d-grid-best-practices\\\/\"},\"author\":{\"name\":\"amanda\",\"@id\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/#\\\/schema\\\/person\\\/92e5698de33907c1204cddc3ac9ff315\"},\"headline\":\"Saf-D-Grid\u00ae: Best Practices for Adding Protection\",\"datePublished\":\"2025-09-14T23:47:14+00:00\",\"dateModified\":\"2026-05-22T18:20:02+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/saf-d-grid-best-practices\\\/\"},\"wordCount\":651,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/#organization\"},\"articleSection\":[\"Thought Leadership\"],\"inLanguage\":\"en-IN\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/saf-d-grid-best-practices\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/saf-d-grid-best-practices\\\/\",\"url\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/saf-d-grid-best-practices\\\/\",\"name\":\"Saf-D-Grid\u00ae: Best Practices for Adding Protection\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/#website\"},\"datePublished\":\"2025-09-14T23:47:14+00:00\",\"dateModified\":\"2026-05-22T18:20:02+00:00\",\"description\":\"Saf-D-Grid builds on the proven contact technology used in SB and Powerpole\u00ae connectors by offering features required in 380-400VDC power distribution systems.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/saf-d-grid-best-practices\\\/#breadcrumb\"},\"inLanguage\":\"en-IN\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/saf-d-grid-best-practices\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/saf-d-grid-best-practices\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Saf-D-Grid\u00ae: Best Practices for Adding Protection\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/#website\",\"url\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/\",\"name\":\"Anderson Power\",\"description\":\"Anderson\u2122 is a division of IDEAL Industries, an international leader in high-power interconnect solutions.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-IN\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/#organization\",\"name\":\"Anderson Power\",\"url\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-IN\",\"@id\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.andersonpower.com\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2026\\\/04\\\/2026_AP-Logo-Vertical-white.png\",\"contentUrl\":\"https:\\\/\\\/www.andersonpower.com\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2026\\\/04\\\/2026_AP-Logo-Vertical-white.png\",\"width\":300,\"height\":129,\"caption\":\"Anderson Power\"},\"image\":{\"@id\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/#\\\/schema\\\/person\\\/92e5698de33907c1204cddc3ac9ff315\",\"name\":\"amanda\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-IN\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/986e94d3b210e5455802b28ae0623734776a72944916226cf97b06b013adf34d?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/986e94d3b210e5455802b28ae0623734776a72944916226cf97b06b013adf34d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/986e94d3b210e5455802b28ae0623734776a72944916226cf97b06b013adf34d?s=96&d=mm&r=g\",\"caption\":\"amanda\"},\"url\":\"https:\\\/\\\/www.andersonpower.com\\\/en-in\\\/author\\\/amanda\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Saf-D-Grid\u00ae: Best Practices for Adding Protection","description":"Saf-D-Grid builds on the proven contact technology used in SB and Powerpole\u00ae connectors by offering features required in 380-400VDC power distribution systems.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.andersonpower.com\/en-in\/saf-d-grid-best-practices\/","og_locale":"en_US","og_type":"article","og_title":"Saf-D-Grid\u00ae: Best Practices for Adding Protection","og_description":"Saf-D-Grid builds on the proven contact technology used in SB and Powerpole\u00ae connectors by offering features required in 380-400VDC power distribution systems.","og_url":"https:\/\/www.andersonpower.com\/en-in\/saf-d-grid-best-practices\/","og_site_name":"Anderson Power","article_published_time":"2025-09-14T23:47:14+00:00","article_modified_time":"2026-05-22T18:20:02+00:00","author":"amanda","twitter_card":"summary_large_image","twitter_misc":{"Written by":"amanda","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.andersonpower.com\/en-in\/saf-d-grid-best-practices\/#article","isPartOf":{"@id":"https:\/\/www.andersonpower.com\/en-in\/saf-d-grid-best-practices\/"},"author":{"name":"amanda","@id":"https:\/\/www.andersonpower.com\/en-in\/#\/schema\/person\/92e5698de33907c1204cddc3ac9ff315"},"headline":"Saf-D-Grid\u00ae: Best Practices for Adding Protection","datePublished":"2025-09-14T23:47:14+00:00","dateModified":"2026-05-22T18:20:02+00:00","mainEntityOfPage":{"@id":"https:\/\/www.andersonpower.com\/en-in\/saf-d-grid-best-practices\/"},"wordCount":651,"commentCount":0,"publisher":{"@id":"https:\/\/www.andersonpower.com\/en-in\/#organization"},"articleSection":["Thought Leadership"],"inLanguage":"en-IN","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.andersonpower.com\/en-in\/saf-d-grid-best-practices\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.andersonpower.com\/en-in\/saf-d-grid-best-practices\/","url":"https:\/\/www.andersonpower.com\/en-in\/saf-d-grid-best-practices\/","name":"Saf-D-Grid\u00ae: Best Practices for Adding Protection","isPartOf":{"@id":"https:\/\/www.andersonpower.com\/en-in\/#website"},"datePublished":"2025-09-14T23:47:14+00:00","dateModified":"2026-05-22T18:20:02+00:00","description":"Saf-D-Grid builds on the proven contact technology used in SB and Powerpole\u00ae connectors by offering features required in 380-400VDC power distribution systems.","breadcrumb":{"@id":"https:\/\/www.andersonpower.com\/en-in\/saf-d-grid-best-practices\/#breadcrumb"},"inLanguage":"en-IN","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.andersonpower.com\/en-in\/saf-d-grid-best-practices\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.andersonpower.com\/en-in\/saf-d-grid-best-practices\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.andersonpower.com\/en-in\/"},{"@type":"ListItem","position":2,"name":"Saf-D-Grid\u00ae: Best Practices for Adding Protection"}]},{"@type":"WebSite","@id":"https:\/\/www.andersonpower.com\/en-in\/#website","url":"https:\/\/www.andersonpower.com\/en-in\/","name":"Anderson Power","description":"Anderson\u2122 is a division of IDEAL Industries, an international leader in high-power interconnect solutions.","publisher":{"@id":"https:\/\/www.andersonpower.com\/en-in\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.andersonpower.com\/en-in\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-IN"},{"@type":"Organization","@id":"https:\/\/www.andersonpower.com\/en-in\/#organization","name":"Anderson Power","url":"https:\/\/www.andersonpower.com\/en-in\/","logo":{"@type":"ImageObject","inLanguage":"en-IN","@id":"https:\/\/www.andersonpower.com\/en-in\/#\/schema\/logo\/image\/","url":"https:\/\/www.andersonpower.com\/wp-content\/uploads\/sites\/3\/2026\/04\/2026_AP-Logo-Vertical-white.png","contentUrl":"https:\/\/www.andersonpower.com\/wp-content\/uploads\/sites\/3\/2026\/04\/2026_AP-Logo-Vertical-white.png","width":300,"height":129,"caption":"Anderson Power"},"image":{"@id":"https:\/\/www.andersonpower.com\/en-in\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.andersonpower.com\/en-in\/#\/schema\/person\/92e5698de33907c1204cddc3ac9ff315","name":"amanda","image":{"@type":"ImageObject","inLanguage":"en-IN","@id":"https:\/\/secure.gravatar.com\/avatar\/986e94d3b210e5455802b28ae0623734776a72944916226cf97b06b013adf34d?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/986e94d3b210e5455802b28ae0623734776a72944916226cf97b06b013adf34d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/986e94d3b210e5455802b28ae0623734776a72944916226cf97b06b013adf34d?s=96&d=mm&r=g","caption":"amanda"},"url":"https:\/\/www.andersonpower.com\/en-in\/author\/amanda\/"}]}},"parsely":{"version":"1.1.0","canonical_url":"https:\/\/andersonpower.com\/en-in\/saf-d-grid-best-practices\/","smart_links":{"inbound":0,"outbound":0},"traffic_boost_suggestions_count":0,"meta":{"@context":"https:\/\/schema.org","@type":"NewsArticle","headline":"Saf-D-Grid\u00ae: Best Practices for Adding Protection","url":"http:\/\/www.andersonpower.com\/en-in\/saf-d-grid-best-practices\/","mainEntityOfPage":{"@type":"WebPage","@id":"http:\/\/www.andersonpower.com\/en-in\/saf-d-grid-best-practices\/"},"thumbnailUrl":"","image":{"@type":"ImageObject","url":""},"articleSection":"Thought Leadership","author":[{"@type":"Person","name":"amanda"}],"creator":["amanda"],"publisher":{"@type":"Organization","name":"Anderson Power","logo":""},"keywords":[],"dateCreated":"2025-09-14T23:47:14Z","datePublished":"2025-09-14T23:47:14Z","dateModified":"2026-05-22T18:20:02Z"},"rendered":"<script type=\"application\/ld+json\" class=\"wp-parsely-metadata\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@type\":\"NewsArticle\",\"headline\":\"Saf-D-Grid\\u00ae: Best Practices for Adding Protection\",\"url\":\"http:\\\/\\\/www.andersonpower.com\\\/en-in\\\/saf-d-grid-best-practices\\\/\",\"mainEntityOfPage\":{\"@type\":\"WebPage\",\"@id\":\"http:\\\/\\\/www.andersonpower.com\\\/en-in\\\/saf-d-grid-best-practices\\\/\"},\"thumbnailUrl\":\"\",\"image\":{\"@type\":\"ImageObject\",\"url\":\"\"},\"articleSection\":\"Thought Leadership\",\"author\":[{\"@type\":\"Person\",\"name\":\"amanda\"}],\"creator\":[\"amanda\"],\"publisher\":{\"@type\":\"Organization\",\"name\":\"Anderson Power\",\"logo\":\"\"},\"keywords\":[],\"dateCreated\":\"2025-09-14T23:47:14Z\",\"datePublished\":\"2025-09-14T23:47:14Z\",\"dateModified\":\"2026-05-22T18:20:02Z\"}<\/script>","tracker_url":"https:\/\/cdn.parsely.com\/keys\/andersonpower.com\/p.js"},"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/www.andersonpower.com\/en-in\/wp-json\/wp\/v2\/posts\/1829","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.andersonpower.com\/en-in\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.andersonpower.com\/en-in\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.andersonpower.com\/en-in\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/www.andersonpower.com\/en-in\/wp-json\/wp\/v2\/comments?post=1829"}],"version-history":[{"count":3,"href":"https:\/\/www.andersonpower.com\/en-in\/wp-json\/wp\/v2\/posts\/1829\/revisions"}],"predecessor-version":[{"id":11382,"href":"https:\/\/www.andersonpower.com\/en-in\/wp-json\/wp\/v2\/posts\/1829\/revisions\/11382"}],"wp:attachment":[{"href":"https:\/\/www.andersonpower.com\/en-in\/wp-json\/wp\/v2\/media?parent=1829"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.andersonpower.com\/en-in\/wp-json\/wp\/v2\/categories?post=1829"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.andersonpower.com\/en-in\/wp-json\/wp\/v2\/tags?post=1829"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.andersonpower.com\/en-in\/wp-json\/wp\/v2\/product_cat?post=1829"},{"taxonomy":"industry","embeddable":true,"href":"https:\/\/www.andersonpower.com\/en-in\/wp-json\/wp\/v2\/industry?post=1829"},{"taxonomy":"product-series","embeddable":true,"href":"https:\/\/www.andersonpower.com\/en-in\/wp-json\/wp\/v2\/product-series?post=1829"},{"taxonomy":"product-application","embeddable":true,"href":"https:\/\/www.andersonpower.com\/en-in\/wp-json\/wp\/v2\/product-application?post=1829"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}