Saf-D-Grid® Connector Series

The Power You Need in the Space You Have

 

Built for the Data Centers of Tomorrow

 

Saf-D-Grid delivers maximum power in minimal space. Power your data center’s busways, uninterruptible power supplies, power distribution units, and power supply units with a compact connector built to handle impressive voltage and current. Whether you're working with AC, DC, or high-power architectures, Saf-D-Grid keeps up with your data center’s evolving demands.

 

Our Saf-D-Grid Options

 

Saf-D-Grid

  • Up to 7.2x the power of a C13/C14 in same footprint
  • UL-Rated for disconnect up to 30A and 400V
  • Supports up to 277VAC and 380VDC

     

 

 

Saf-D-Grid Max

  • Provides max amperage in C19/C20 footprint
  • UL-Rated for disconnect up to 40A and 305V
  • Supports up to 277VAC and 380VDC

 

 

 

 

Saf-D-Grid Three-Phase

  • High-power connector engineered for three-phase data centers
  • UL-Rated for disconnect up to 20A
  • Supports up to 480VAC three-phase in a C13/C14 footprint

 

 

Saf-D-Grid Low Clearance

  • Compact design perfect for tight cabinet installations
  • Reduced mating face height with stronger panel retention latches
  • Delivers the same standout power density as the original Saf-D-Grid

 

 

Saf-D-Grid Output Key

  • Extra PDU key prevents accidental PDU loopback
  • Color-coded for easy identification and installation
  • Delivers the same standout power density as the original Saf-D-Grid

 

 

 

AP Blue Gradient background
  • Power density - Delivers up to 400V AC or DC at up to 30A through the footprint of an IEC 60320 C13
  • Touch safe interface - On both receptacle and plug
  • Hot plug rated
  • Arcing protection
  • Integral latch - Connectors cannot be accidentally unmated
  • Make-first/break-last connection
  • Rated at 90ºC and up to 105ºC - Higher tolerance from hot aisle temperatures

 

See What's New in the Data Center Industry

 

The Connector Designed to Grow
with Your Data Center

The demand on data centers is growing, and every square foot counts. Learn about the advantages of implementing compact Saf-D-Grid connectors designed to save you precious rack space.

High-Voltage Data Center Architectures: Advantages and Challenges of Adopting 480VAC Three-Phase

As power demands increase, data centers are exploring unique power architectures. Read about a solution that runs 480VAC three-phase power all the way to the PDUs — and the unique Saf-D-Grid connector designed to support it.

NEED A CUSTOM SOLUTION?

Our experts can customize Saf-D-Grid for your data center’s unique needs.